Conference article

Simulation study of a digital hydraulic independent metering valve system on an excavator

Miikka Ketonen
Laboratory of Automation and Hydraulics, Tampere University of Technology, Tampere, Finland

Matti Linjama
Laboratory of Automation and Hydraulics, Tampere University of Technology, Tampere, Finland

Download articlehttp://dx.doi.org/10.3384/ecp17144136

Published in: Proceedings of 15:th Scandinavian International Conference on Fluid Power, June 7-9, 2017, Linköping, Sweden

Linköping Electronic Conference Proceedings 144:13, p. 136-146

Show more +

Published: 2017-12-20

ISBN: 978-91-7685-369-6

ISSN: 1650-3686 (print), 1650-3740 (online)

Abstract

Independent metering valve (IMV) control of working hydraulic systems in mobile machines has been studied for more than two decades and during the past few years it has also been adopted to commercial excavators. The main advantages of the IMV systems, compared to load sensing and open centre systems are the possibility of optimizing the ressure losses of the metering edges and the possibility of re-routing the hydraulic energy between actuators. Energy re-routing can be realized without storing the energy to accumulators and thus avoiding the losses of additional routing valves and energy conversions. IMV combined with a hybrid system allows even more improved energy efficiency. igital hydraulic IMV (D-IMV) allows additional benefits to the IMV systems with more fault-tolerant operation with robust components, faster and more precise control and leak-free valves.

The purpose of this study is to apply a D-IMV system to a midsize (20t) excavator and to study the differences in energy consumption of the working hydraulic system with four actuators. This paper presents the controller designed for the D-IMV and a simulation model for analysing the system. The energy consumption of the D-IMV is compared to the measured energy consumption of a state-of-the-art excavator with a load-sensing hydraulic system.

The Controller of the D-IMV system is realized with a sub-optimal mode control, so that instead of calculating and optimizing the total energy consumption of all possible mode combinations, simpler control logic is defined to remove the complex structure of the controller and ease the computational burden. Simulation study shows that the hydraulic input energy can be reduced 28-42% compared to a standard LS-controlled excavator. Detailed analysis of where the reduction emerges is presented.

Keywords

Digital hydraulics, Independent metering valve, mobile hydraulics, excavator

References

[1] Lettini, A., Havermann, M., Guidetti, M., & Fornaciari, A. (2010). Electro-Hydraulic Load Sensing: a Contribution to Increased Efficiency Through Fluid Power on Mobile Machines. Fuidotecnica, 345.

[2] Vukovic, M., Leifeld, R., and Murrenhoff, H., 2016. STEAM a hydraulic hybrid architecture for excavators. 10th International Fluid Power Conference (10. IFK), 8–10 March, Dresden, Germany.

[3] Linjama, M., Vihtanen, H-P., Vilenius, M. Secondary controlled multi-chamber hydraulic cylinder, The 11th Scandinavian International Conference on Fluid Power, SICFP’09, June 2-4, 2009, Linköping, Sweden

[4] K. Heybroek, G. Vael, and J.-O. Palmberg, “Towards resistance - free hydraulics in construction machinery,” in The 8th International Fluid Power Conference, 8. IFK, Dresden, Germany, 2012.

[5] C. Williamson and M. Ivantysynova, “Power optimization for multi-actuator pump- controlled systems,” in The 7th International Fluid Power Conference, 7. IFK, Aachen, Germany, 2010.

[6] K. Einola and M. Erkkilä, “Dimensioning and control of a hydraulic hybrid system of a cut-to-length forest harvester,” in The 9th International Fluid Power Conference, 9. IFK, Aachen, Germany, 2014

[7] Lin, T., Wang, Q., Hu, B., & Gong, W. (2010). Development of hybrid powered hydraulic construction machinery. Automation in Construction, 19(1), 11–19. https://doi.org/10.1016/j.autcon.2009.09.005

[8] Eriksson, B., Palmberg, J.-O., Individual metering fluid power systems: Challenges and opportunities. Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering, 225:196–211, 2011.

[9] Nielsen, B. (2005). Controller Development for a Separate Meter-In Separate Meter-Out Fluid Power Valve for Mobile Applications, 237. Available http://vbn.aau.dk/files/74051350/brian_nielsen.pdf

[10] Heybroek, K., Larsson, J., Palmberg, J.-O., Mode Switching and energy recuperation in open-circuit pump control. In The Tenth Scandinavian International Conference on Fluid Power, Tampere, Finland, May 21-23 2007. Available http://liu.divaportal.org/smash/get/diva2:133010/FULLTEXT01.pdf

[11] Caterpillar website, http://www.cat.com/en_ID/news/machine-pressreleases/cat-sup-174-sup-336ehhydraulichybridexcavatordeliversnocompromis.html, visited 10.1.2017

[12] Linjama, M., Digital fluid power - state of the art. In The Twelfth Scandinavian International Conference on Fluid Power, Tampere, Finland, May 18-20 2011, available: https://pdfs.semanticscholar.org/a1a3/afd27352191866b5614af9abea93ff5a9cf7.pdf

[13] Huova, M., Ahopelto, M., Ketonen, M., Ahola, V., Linjama, M., Huhtala, K., Characteristics of digital hydraulics with commercial controllers, The Seventh Workshop on Digital Fluid Power, February 26-27, 2015, Linz, Austria.

[14] Karvonen, M. (2016). Energy Efficient Digital Hydraulic Power Management of a Multi Actuator System. (Tampere University of Technology. Publication; Vol. 1384). Tampere University of Technology.

[15] JCMAS H020. Japan Construction Mechanization Association. Standard for of excavator fuel efficiency measurement procedure. 2010.

Citations in Crossref